Spesifikasi Fluke 902 FC True rms HVAC Clamp Meter


 Alat Laboratorium Umum



SPECIFICATION Fluke 902 FC True rms HVAC Clamp Meter



Function



A ac (via Jaw)



Resolution 0.01/0.1 A



Accuracy 2.0% ±5 digit (45-65 Hz)

2.5% ±5 digit (65-400 Hz)



Range 60.00/600.0 A

Crest Factor (50Hz or 60Hz) 2.5 MIN@220 A

3.0 MIN@180 A

> 1.4 MIN@600 A

Add 2% for CF>400 A



V ac

Resolution 0.1 V

Accuracy 1.5% ±5 digits

Range 600.0 V



V dc



Resolution 0.1 V

Accuracy 1.5% ±5 digits

Range 600.0 V

Ohms

Resolution 0.1/1/10

Accuracy 1% ±5 digits

Range 600/6000/60.00 kΩ

Capacitance

Resolution 0.1/1 µF

Accuracy 1% ±4 digits

Range 100.0/1000 µF

µA

Resolution 0.1 µA

Accuracy 1% ±5 digits

Range 200 µA

Contact temperature

Resolution 0.1 C/F

Accuracy 1% ±8 digits

Range -10 to 400 °C (14 °F to 752 °F)

Continuity beeper

Beeper volume 75 dBA nom. 15 cm. from case front

On threshold <=30 Ω

Mechanical and General Specifications

Maximum voltage between any terminal and earth ground 1000 V

Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6

Temperature Operating: -10 °C to +50 °C (14 °F to +122 °F)

Storage: -40 °C to +60 °C (-40 °F to +140 °F)

O



perating humidity Non condensing



(< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104°F to 122 °F))



Altitude Operating: 3,000 m (9,842 ft)



Storage: 12,000 m (39,370 ft)



Dimensions 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)



Weight (meter only) 419 g (15 oz)



Safety



IEC 61010-1, Pollution Degree 2

IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V

IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V



IP Rating IEC 60529: IP30, non-operating



Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE



Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR



11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47



CFR 15 subpart B. This product is considered an exempt device per clause 15.103.



 



Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C