PT ANDALAN BANGUN SEJAHTERA

sql
HI98303
Hover to Zoom

22 Feb 2019
American Samoa
1 UNIT
IDR CALL

Spesifikasi

PH Meter

Details

The DiST 3 features a large multi-level LCD which displays both electrolytic conductivity (EC) and temperature readings simultaneously. The EC readings are displayed with a 1 µS/cm resolution and with an accuracy of ±2% full scale. The conductivity range of the HI98303 is from 0 to 2000 µS/cm. An exposed temperature sensor allows for rapid automatic temperature compensated conductivity measurements. Temperature can be set to display in ℃ or ℉. The LCD screen has stability and calibration tag indicators. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

Conductivity readings are performed by an amperometric graphite electrode that resists oxidation, providing better repeatability in measurements. The use of graphite also reduces the polarization effect common with amperometric testers that use two stainless steel pins.

Calibration is performed by pressing the dedicated calibration button. Once in calibration mode submerge the probe in 1413 µS/cm calibration standard. When the standard value is recognized and stability reached, the meter will automatically accept and store the calibration value.

Setup options include automatic shut-off timing and temperature unit displayed. Automatic shut-off options are to turn the meter off after 8 minutes, 60 minutes, or disabled. To enter the setup mode the user presses a button located in the battery compartment.

 

Specifications

Conductivity Range0 to 2000 µS/cm
Conductivity Resolution1 µS/cm
Conductivity Accuracy (@25ºC/77ºF)±2% F.S.
Temperature Range0.0 to 50.0°C / 32.0 to 122.0°F
Temperature Resolution0.1°C / 0.1°F
Temperature Accuracy (@25ºC/77ºF)±0.5°C /±1°F
Calibrationautomatic, one-point
Temperature Compensationautomatic from 0 to 50°C (32 to 122°F)
Battery Type/LifeCR2032 3V Li-Ion (1 pc.) / approximately 250 hours of continuous use
Auto-offafter 8 minutes, 60 minutes, disabled
Environment0 to 50°C (32 to 122°F); RH max 100%
Dimensions160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
Weight68 g (2.4 oz.) without battery
Ordering InformationHI98303 is supplied with protective cap, 1413 µS/cm calibration solution sachet (4), CR2032 battery, instrument quality certificate and instructional manual.
Warranty1 year

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot