InfraCal 2 ATR-SP - Oil In Water / Soil Analyzer
Hover to Zoom

Jual InfraCal 2 ATR-SP - Oil In Water / Soil Analyzer



Spesifikasi InfraCal 2 ATR-SP - Oil In Water / Soil Analyzer

InfraCal 2 ATR-SP - Oil In Water/Soil Analyzer

TOG/TPH in water/soil, FOG in wastewater

Alat Laboratorium Air

The InfraCal Model ATR-SP is recommended for measuring oil in water, TPH in soil or FOG in wastewater concentration levels when using hexane, pentane or Vertrel MCA as the extracting solvent. Measurement data obtained with this analyzer will correlate to EPA Method 1664 as both procedures are based on evaporation techniques and measuring the residual oil and grease. The analyzer is equipped with a built-in cubic zirconia horizontal attenuated total reflection (HATR) stainless steel sample stage.   The InfraCal 2 ATR-SP is a direct replacement for the original InfraCal HATR-T2 used worldwide for the determination of TOG/TPH in water and soil.

  • Minimum Detection Limit Water: 0.3 ppm
  • Minimum Detection Limit Soil: 3 ppm
  • Method Compares: EPA 1164 & ISO 9377-2
  • Solvents: Hexane, pentane, cyclohexane & Vertrel MCA

Highlights

As offshore oil wells age, the increase of produced water challenges wastewater treatment systems.  In order to ensure oil levels in the water are under the regulatory limit, it is important to do regular testing.  Infrared analysis has been used for off-shore oil in water measurements for over 45 years.  Infrared is an accepted oil content measurement as it is least affected by changes in produced water composition.

For industrial pretreatment of wastewater and public water treatment plants a simplified procedure for monitoring FOG discharges can avoid fines, sanitary sewer overflows (SSOs) and give on-site results in less than 15 minutes rather than waiting days or weeks for an off-site laboratory result.

The InfraCal 2 has added features such as touch screen display, data storage and transfer, a multi-language interface and password protected settings.  The internal battery pack allows for portability and up to 6 hours continuous use.

Operating Principle

The InfraCal 2 ATR-SP analyzer is designed to measure solvent extractable material (oil and grease) by infrared determination in water or soil using hexane, pentane, cyclohexane or Vertrel MCA for the extraction procedure. A detector with a fixed 3.4 μm (2940 cm-1) filter is used to measure oil and grease concentrations. The ATR-SP correlates with EPA Methods 1664 as well as with the ASTM D7066 Method and EPA 413.1 and 418.1.  

The ATR-SP makes use of the fact that oil and grease can be extracted from water or soil through the use of an appropriate solvent and extraction procedure. The extracted hydrocarbons absorb infrared energy at a specific wavelength and the amount of energy absorbed is proportional to the concentration of hydrocarbons in the solvent. The analyzer can be calibrated to read out directly in the desired units such as %, ppm, mg/L or mg/kg.  

The touchscreen display includes the capability for multiple calibrations, a wizard guide for calibration, multilevel user database, multiple languages with user preference selection, high/low alarm and control limits, and measurements stored in a history table for recall or export to a flash or serial port.

Specifications

ItemSpecifications
Analytical Wavelength/Wave Number3.4 µm, 2930 cm-1
Power Requirements18 volts DC, 3.3 amps, internal battery pack available
Power SupplyUniversal AC/DC provided
Weight5.8 lb. (2.6 kg) with battery -7.0 lbs (3.2 kg)
Dimensions(17 cm) x 7.8" (19.8 cm) x 5.2" (13.2 cm)
Suggested Operating Range5°C - 40°C
Measurement Range 
For Water0.3-1000+ ppm
For Soil3-5000+ ppm
Analysis Time10-15 minutes, including extraction process
Instrument Repeatability±0.2 ppm
Communication PortUSB

 

New High Range Measurement of Oil In Water or Soil

The InfraCal 2 analyzer with an ATR sample stage can now be used for measuring the 0.5-10% range of oil in water or soil. The sample is extracted using a solvent that does not have an infrared absorbance at the hydrocarbon wavelength and, therefore, does not require evaporation. Measuring the extract directly in the solvent, instead of evaporating off the solvent, allows for percent range measurements with the same ATR sample stage used to measure the ppm levels.

  • Measurement Range Water: 0.5 – 10%
  • Measurement Range Soil: 0.5 – 10%
  • Solvents: S-316, Tetrachloroethylene

InfraCal 2 ATR-SP (TOG/FOG/TPH) Analyzer

  
InfraCal 2 Model ATR-SP
Minimum Detection Limit Water0.3 ppm
Minimum Detection Limit Soil3 ppm
For use with Solvent(s):Hexane, pentane, cyclohexane, Vertrel MCA
Method Compares to:EPA 1664 & ISO 9377-2
  
405-2034ATR-SP Uncalibrated; Includes Internal Battery, Auto Adapter, 100 U Syringe, Universal Power Supply
405-2034-44Includes a factory calibration using Hexane TOG/TPH High Range Calibration Standards for samples containing primarily petroleum hydrocarbons; Includes Internal Battery, Auto Adapter, 100 ul Syringe, Universal Power Supply, Dust Cover Includes 1 Calibration Range for Water, Soil Calibration can be added for additional $175 charge: Water: 10, 25, 50, 100, 150, and 200 mg/L Soil: 100, 250, 500, 1000, 1500, and 2000 mg/kg
405-2034-8144Includes a factory calibration using Hexane TOG/TPH Low & High Range Calibration Standards for samples containing primarily petroleum hydrocarbons; Includes Internal Battery, Auto Adapter, 100 ul Syringe, Universal Power Supply, Dust Cover Includes 2 Calibration Ranges for Water, Soil Calibration can be added for additional $175 charge: Water: 0.5, 1, 2.5, 5.0, and 7.5 mg/L Water: 10, 25, 50, 100, 150, and 200 mg/L Soil: 100, 250, 500, 1000, 1500, and 2000 mg/kg
405-2034-72Includes a factory calibration using Hexane TOG/FOG Calibration Standards for wastewater that contains animal and/or plant oils; Includes Internal Battery, Auto Adapter, 100 ul Syringe, Universal Power Supply, Dust Cover Includes 1 Calibration Range for Water: Water: 10, 25, 50, 100, 150, and 200mg/L
Optional Calibrations: 
403-1081CFactory Calibration using Hexane Low Range Calibration Standards (403-1081) Water: 0.5, 1, 2.5, 5.0, and 7.5 mg/L
 Accessories
403-0013Carrying Case for InfraCal Analyzers with pre-diced pluck foam. 18.5" x 14.6" x 8"; 10 lbs.
403-1086Dust Cover
 Calibration Standards Sets
403-1081Low Range Hexane TOG/TPH Five Point Calibration Standard Set Light Mineral Oil in hexane prepared by a certified laboratory. The set contains 6 standards from 0.5mg/L to 7.5 mg/L (ppm) for water and 5 mg/kg to 75 mg/kg for soil, includes solvent blanks. Recommended for customers in the petroleum industry who are primarily measuring low levels of petroleum hydrocarbons in water or soil.
403-1044Hexane TOG/TPH Six point Calibration Standard Set Light Mineral Oil in N-Hexane prepared by a certified laboratory for TOG/TPH Analysis. Nominal concentration values are 100 mg/kg (ppm), 250 mg/kg, 500 mg/kg, 1000 mg/kg, 1500 mg/kg and 2000 mg/kg for soil assuming a 1:1 extraction ratio; and 10 mg/L (ppm), 25 mg/L, 50 mg/L, 100 mg/L, 150 mg/L and 200 mg/L for water assuming a 10:1 extraction ratio. The set contains 6 standards along with a solvent blank in 2 ml flame sealed ampoules. Recommended for customers in the petroleum industry who are primarily measuring petroleum hydrocarbons in water or soil.
403-1072Hexane TOG/FOG Six Point Calibration Standard Set 50:50 Soybean Oil/Hexadecane in N-Hexane prepared by a certified laboratory. Nominal concentration values are 10 mg/L (ppm), 25 mg/L, 50 mg/L,100 mg/L, 150 mg/L and 200 mg/L for water assuming a 10:1 extraction ratio. The set contains 6 standards along with a solvent blank in 2 ml flame sealed ampoules. Recommended for customers measuring non-polar (petroleum) and polar (animal and vegetable fats) hydrocarbons for TOG or FOG measurements such as municipal wastewater or industrial wastewater that includes animal and vegetable fats.
  
 Field Sampling Kits
403-1011Field Sampling Kit for TOG-TPH in Water
 100ml Graduated Cylinder
 25ml Graduated Cylinder
 125 ml Wash Bottle 
 20ml Beaker 
 100ul Syringe Disposable Pipettes (100 pc.)
 Glass Funnel 
 177ml Graduated Bottles (48 pc) 
 Septa Caps (48 pc) 
 Sodium Sulfate, 500g 
 Silica Gel, 500g 
 Filter Paper, 100pc
  
403-1010Field Sampling Kit for TOG-TPH in Soil
 100ml Graduated Cylinder 
 25ml Graduated Cylinder 
 125 ml Wash Bottle 
 20ml Beaker 
 100ul Syringe Disposable Pipettes (100 pc.) 
 Glass Funnel 
 40ml Vials (72 pc.) 
 Pocket Balance 
 Sample Spatula 
 Silica Gel, 500g 
 Filter Paper, 100pc 
 60ml Syringe Cartridge & Plunger (100)
  
403-1083Field Sampling Kit for Sub-ppm in Water
 10ml Glass Luer-Lok Syringe
 Filters for Glass Luer-Lok Syringe (100 pc
 This kit is to be used in addition to 403-1063 for sub-ppm in water sampling