Specifications: 572-2 High Temperature Infrared Thermometer

Infrared Measurements
Infrared temperature range-30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
≥ -10°C to < 0°C: ±2°C
< -10°C: ±3°C
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥ 14°F to < 32°F: ±4°F
< 14°F: ±6°F
IR repeatability±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution0.1°C / 0.1°F
Distance: Spot60:1 (calculated at 90% energy)
Minimum spot size19 mm
Laser sightingOffset dual laser, output < 1 mW
Spectral response8 μm to 14 μm
Response time (95%)< 500 ms
EmissivityDigitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range-270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)< -40°C: ±(1°C + 0.2° / 1°C)
≥ -40°C: ±1% or 1°C, whichever is greater
< -40°F: ±(2°F + 0.2° / 1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple0.1°C / 0.1°F
K-type thermocouple repeatability±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Measurement Options
Hi/Low alarmsAudible and two-color visual
Min/Max/Avg/DifYes
Switchable celsius and fahrenheitYes
BacklightTwo levels, normal and extra bright for darker environments
Probe inputK-type thermocouple simultaneous display of probe and IR temperature
Trigger lockYes
Data storage99 points
DisplayDot matrix 98 x 96 pixels with function menus
CommunicationUSB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe)-40°C to 260°C (-40°F to 500°F)
Accuracy±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and complianceIEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-20°C to 60°C (-4°F to 140°F)
Relative humidity10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude2000 meters above mean sea level
Weight0.322 kg (0.7099 lb)
Power2 AA batteries
Battery life8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)