sql

ProSolo Optical Dissolved Oxygen and Conductivity Meter YSI

Rp. 100
Update Terakhir
30 Agu 2023
Pembelian Min
1 Unit
Kategori
YSI
ProSolo Specifications 
Dimensions8.3 cm width x 21.6 cm length x 5.6 cm depth; 567 g (with battery)
Power

Rechargeable lithium-ion battery pack provides ~48 hours with the handheld only;

Battery recharge time is ~ 9 hours with the AC power adapter;

The instrument can also be powered via AC or external power through the USB port

Operating Temperature0 to 50°C
Storage Temperature

0 to 45°C with battery installed;

0 to 60°C without battery installed

Display

Color, LCD graphic display;

3.9 cm width x 6.5 cm height

Memory>100,000 data sets

Barometer

Units: mmHg, inHg, mbar, psi,
kPa, atm

Range: 375 to 825 mmHg;

Accuracy: ±1.5 mmHg from 0 to 50°C;

Resolution: 0.1 mmHg;

Sites and Data ID

100 user-defined sites and 100 user-defined data ID tags;

Site pictures can be sent to the handheld via KorDSS Software

Calibration Records400 detailed calibration records can be stored and are available to view, download, and print (printing only available via KorDSS Software)
LanguagesEnglish, Spanish, German, French, Italian, Norwegian, Portuguese, Japanese,
Chinese (Simplified & Traditional), Korean, Thai
CertificationsCEC, CE; RoHS; IP-67; WEEE; FCC; UN Part III, Section 38.3, Test methods for lithium-ion batteries (Class 9)
WarrantyNMEA 0183; requires user-supplied GPS and YSI 6115 Y-cable
ODO/CT Specifications 
Size2.46 cm diameter, cable options for 1, 4, 10, 20, 30, 50, and 100 m lengths

Dissolved Oxygen

(Optical luminescence)
Units: % saturation, % saturation
local, mg/L, ppm

Range: 0 to 500%, 0 to 50 mg/L

Accuracy: 0 to 200%: ±1% of reading or 1% saturation, whichever is greater

200 to 500%: ±8% of reading

0 to 20 mg/L: ±0.1 mg/L or 1% of reading, whichever is greater

20 to 50 mg/L: ±8% of reading

Resolution: 0.01 mg/L and 0.1%, or 0.1 mg/L and 1% (auto-adjusts based on range)

Temperature

(Thermistor)
Units: °C, °F, K

Range: -5 to 70°C (temperature compensation range for DO mg/L measurement: -5 to 50°C )

Accuracy: ±0.2°C

Resolution: 0.1°C or 0.1°F (auto-adjusts based on range)

Conductivity

(Four nickel electrode cell)
Units: μS/cm, mS/cm

Range: 0 to 200 mS/cm

Accuracy: 0 to 100 mS/cm ±0.5% of reading or .001 mS/cm, whichever is greater

100 to 200 mS/cm ±1.0% of reading

Resolution: 0.001, 0.01, or 0.1 mS (range dependent)

Specific Conductance

Units: μS/cm, mS/cm

Range: 0 to 200 mS/cm

Accuracy: 0 to 100 mS/cm ±0.5% of reading or .001 mS/cm, whichever is greater

100 to 200 mS/cm ±1.0% of reading

User selectable reference temperature (15 to 25°C; default 25°C) and compensation
coefficient (0 to 4%/°C; default 1.91%)

Resolution: 0.001, 0.01, 0.1 mS/cm

Warranty2 years on cable, probe, and ODO sensor cap

Alat Laboratorium Air

Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Minta Penawaran
Produk Siap di Pesan
Rp 0
1